TRION(3) modules

Our multi-channel signal conditioning modules provide separate A/D conversion on each channel and up to 24-bit resolution with anti-aliasing filters. Perfect simultaneous sampling for all analog input modules. You are absolutely flexible with the user-exchangeable TRION3 & TRION modules – just insert them in your suitable DEWETRON DAQ system.

There are two module series: The highspeed  TRION3  modules are only compatible with the DEWE3 chassis. But TRION modules can be used in both, DEWE3 and DEWE2 chassis.

 
belongs to: Products & Drivers 
You have to be logged in to access the downloads. Please use the login form on the top of the page.
DEWETRON TRION R7.0.0 Setup.exe (DEWETRON-TRION-Applications-7.0.0.2733.exe - 205.93 MB)
md5: fdd1ce29cb91536336e1fda6f346a5fb
Version: R7.0.0
Releasedate: 2024-02-14
OS Compatibility: Windows

Show notes

## 2024-02-01 Release Notice DEWETRON TRION API R7.0.0

Revision: c8730c64bd0f421a4b0a87b70977e5b072fa9e1e

Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 7.0.0.2733
DEWETRON TRION API              | 7.0.0.2733
DEWETRON TRION driver           | 7.0.0.2733
DEWETRON DEWE2 driver           | 7.0.0.2733

## Files
DEWETRON-TRION-Applications-7.0.0.2733.exe

## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.0.0 or higher
* Windows 10 64-Bit or better

## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade

## New Features and most important bugfixes
* Dewetron Explorer
  * New X icon, better dark mode, splashscreen
  * Improved network configuration
    * Added set to default (default static, default dhcp)
    * Allow configuration even if ip seetings do not match (TRIONet, NEXDAQ)
* CAN-FD bittiming added
* Fix: ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected
* Fix: ID002 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal


## Known Limitations

## New Firmwares

HW Support TRION modules        | Firmware
--------------------------------|-----------
TRION3-1820-MULTI-4-D           | FW: x0043
TRION3-1820-MULTI-8-L0B         | FW: x0043
TRION3-1850-MULTI-4-D           | FW: x0043
TRION3-1850-MULTI-8-L0B         | FW: x0043
TRION3-1801-MULTI-8-L0B         | FW: x0043
TRION-1820-MULTI-4-D            | FW: x0043

HW Support DEWE3 chassis        | Firmware
--------------------------------|-----------
DEWE3-A4                        | FW: x0038   MCU: 0x01000109
DEWE3-M4                        | FW: x0038   MCU: 0x01000109

 

DEWETRON TRION R7.0.0 Zip (DEWETRON TRION R7.0.0.zip - 205.73 MB)
md5: 5cdf91dc5bb1b2065bdf009368783516
Version: R7.0.0
Releasedate: 2024-02-14
OS Compatibility: Windows

Show notes

## 2024-02-01 Release Notice DEWETRON TRION API R7.0.0

Revision: c8730c64bd0f421a4b0a87b70977e5b072fa9e1e

Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 7.0.0.2733
DEWETRON TRION API              | 7.0.0.2733
DEWETRON TRION driver           | 7.0.0.2733
DEWETRON DEWE2 driver           | 7.0.0.2733

## Files
DEWETRON-TRION-Applications-7.0.0.2733.exe

## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.0.0 or higher
* Windows 10 64-Bit or better

## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade

## New Features and most important bugfixes
* Dewetron Explorer
  * New X icon, better dark mode, splashscreen
  * Improved network configuration
    * Added set to default (default static, default dhcp)
    * Allow configuration even if ip seetings do not match (TRIONet, NEXDAQ)
* CAN-FD bittiming added
* Fix: ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected
* Fix: ID002 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal


## Known Limitations

## New Firmwares

HW Support TRION modules        | Firmware
--------------------------------|-----------
TRION3-1820-MULTI-4-D           | FW: x0043
TRION3-1820-MULTI-8-L0B         | FW: x0043
TRION3-1850-MULTI-4-D           | FW: x0043
TRION3-1850-MULTI-8-L0B         | FW: x0043
TRION3-1801-MULTI-8-L0B         | FW: x0043
TRION-1820-MULTI-4-D            | FW: x0043

HW Support DEWE3 chassis        | Firmware
--------------------------------|-----------
DEWE3-A4                        | FW: x0038   MCU: 0x01000109
DEWE3-M4                        | FW: x0038   MCU: 0x01000109

 

DEWETRON TRION R6.7.3 Setup.exe (DEWETRON-TRION-Applications-6.7.3.2897.exe - 204.15 MB)
md5: 22ddaaa0e41e6d1a667bec44566af072
Version: R6.7.3
Releasedate: 2024-02-14
OS Compatibility: Windows

Show notes

## 2023-02-14 Release Notice DEWETRON TRION API R6.7.3

Revision: 7aa6f0e1381c890da5d0df82d545e1a3cac015d7

Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 6.7.3.2897
DEWETRON TRION API              | 6.7.3.2897
DEWETRON TRION driver           | 6.7.3.2897
DEWETRON DEWE2 driver           | 6.7.3.2897

## Files
DEWETRON-TRION-Applications-6.7.3.2897.exe

## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R6.7.3 or higher
* Windows 10 64-Bit or better

## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade

## New Features and most important bugfixes
* Fix: ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected
* Fix: ID002 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal


## New Firmwares

HW Support TRION modules        | Firmware
--------------------------------|-----------
TRION3-1820-MULTI-4-D           | FW: x0043
TRION3-1820-MULTI-8-L0B         | FW: x0043
TRION3-1850-MULTI-4-D           | FW: x0043
TRION3-1850-MULTI-8-L0B         | FW: x0043
TRION3-1801-MULTI-8-L0B         | FW: x0043
TRION-1820-MULTI-4-D            | FW: x0043

HW Support DEWE3 chassis        | Firmware
--------------------------------|-----------
DEWE3-A4                        | FW: x0038   MCU: 0x01000109
DEWE3-M4                        | FW: x0038   MCU: 0x01000109

DEWETRON TRION R6.7.3 Zip (DEWETRON TRION R6.7.3.zip - 203.96 MB)
md5: fe738bab54b1315ffb7ab5096e8003eb
Version: R6.7.3
Releasedate: 2024-02-14
OS Compatibility: Windows

Show notes

## 2023-02-14 Release Notice DEWETRON TRION API R6.7.3

Revision: 7aa6f0e1381c890da5d0df82d545e1a3cac015d7

Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 6.7.3.2897
DEWETRON TRION API              | 6.7.3.2897
DEWETRON TRION driver           | 6.7.3.2897
DEWETRON DEWE2 driver           | 6.7.3.2897

## Files
DEWETRON-TRION-Applications-6.7.3.2897.exe

## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R6.7.3 or higher
* Windows 10 64-Bit or better

## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade

## New Features and most important bugfixes
* Fix: ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected
* Fix: ID002 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal


## New Firmwares

HW Support TRION modules        | Firmware
--------------------------------|-----------
TRION3-1820-MULTI-4-D           | FW: x0043
TRION3-1820-MULTI-8-L0B         | FW: x0043
TRION3-1850-MULTI-4-D           | FW: x0043
TRION3-1850-MULTI-8-L0B         | FW: x0043
TRION3-1801-MULTI-8-L0B         | FW: x0043
TRION-1820-MULTI-4-D            | FW: x0043

HW Support DEWE3 chassis        | Firmware
--------------------------------|-----------
DEWE3-A4                        | FW: x0038   MCU: 0x01000109
DEWE3-M4                        | FW: x0038   MCU: 0x01000109

DEWETRON Issues and Errata (IssuesAndErrata.pdf - 169 KB)
md5: b0ff5a6bb91090d5c3bbccc34421669e
Version: R6.7.1
Releasedate: 2023-12-04

Show notes

Online: https://docs.dewetron.cloud/doc/errata/index.html

Known Issue:
TRION(3)-18xx-MULTI: high-pass filter not working except 150 mHz (0,15 Hz)
Please use 150 mHz for correct function

(Has Critical Issue, see Notes) DEWETRON TRION R6.7.1 Setup.exe (DEWETRON-TRION-Applications-6.7.1.1582.exe - 194.41 MB)
md5: e40a1343189f546d5975c1e967f354be
Version: R6.7.1
Releasedate: 2023-10-23
OS Compatibility: Windows

Show notes

Known Issue:
TRION(3)-18xx-MULTI: high-pass filter not working except 150 mHz (0,15 Hz)
Please use 150 mHz for correct function


## 2023-10-23 Release Notice DEWETRON TRION API R6.7.1

Revision: 1ee33ea7162d4418af9de534a019b5426b815472

Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 6.7.1.1582
DEWETRON TRION API              | 6.7.1.1582
DEWETRON TRION driver           | 6.7.1.1582
DEWETRON DEWE2 driver           | 6.7.1.1582

## Files
DEWETRON-TRION-Applications-6.7.1.1582.exe

## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R6.7.1 or higher
* Windows 10 64-Bit or better

## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade

## New Features and most important bugfixes
* TRION driver fix for last 32bit addressable page (Debian Linux OS)

## Known Limitations
* None

DEWETRON TRION R6.6.0 Setup.exe (DEWETRON-TRION-Applications-6.6.0.632.exe - 180.57 MB)
md5: 3d7067cd6ebce74fc378d5b29e0e19cc
Version: R6.6.0
Releasedate: 2023-08-04
OS Compatibility: Windows

Show notes

## 2023-07-24 Release Notice DEWETRON TRION API R6.6.0

Revision: 98efc4da43ef96f4b384bda3c6ae1c658a374fae

Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 6.6.0.632
DEWETRON TRION API              | 6.6.0.632
DEWETRON TRION driver           | 6.6.0.632
DEWETRON DEWE2 driver           | 6.6.0.632

## Files
DEWETRON-TRION-Applications-6.6.0.632.exe

## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R6.6 or higher
* Windows 10 64-Bit or better

## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade

## New Features and most important bugfixes
* TRION(3)-1820-MULTI:
  * Input coupling (highpass filter) overshoot fixed with 0.15Hz filter
* TRIONet3 support
* TRION(3)-Power:
  * TRION SUB-XV support
* TRION3-SUB-8:
  * TRION SUB-XV support

## Known Limitations
* None

(Has Critical Issue, see Notes) DEWETRON TRION R6.7.1 Zip (DEWETRON TRION R6.7.1.zip - 194.21 MB)
md5: 62743ffddad6f659135616521e591b68
Version: R6.7.1
Releasedate: 2023-10-23
OS Compatibility: Windows

Show notes

Known Issue:
TRION(3)-18xx-MULTI: high-pass filter not working except 150 mHz (0,15 Hz)
Please use 150 mHz for correct function

 

## 2023-10-23 Release Notice DEWETRON TRION API R6.7.1

Revision: 1ee33ea7162d4418af9de534a019b5426b815472

Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 6.7.1.1582
DEWETRON TRION API              | 6.7.1.1582
DEWETRON TRION driver           | 6.7.1.1582
DEWETRON DEWE2 driver           | 6.7.1.1582

## Files
DEWETRON-TRION-Applications-6.7.1.1582.exe

## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R6.7.1 or higher
* Windows 10 64-Bit or better

## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade

## New Features and most important bugfixes
* TRION driver fix for last 32bit addressable page (Debian Linux OS)

## Known Limitations
* None

DEWETRON TRION R6.6.0 Zip (DEWETRON TRION R6.6.0.zip - 180.37 MB)
md5: 6cdc6cdae53403e12597cdc7177192db
Version: R6.6.0
Releasedate: 2023-08-04
OS Compatibility: Windows

Show notes

## 2023-07-24 Release Notice DEWETRON TRION API R6.6.0

Revision: 98efc4da43ef96f4b384bda3c6ae1c658a374fae

Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 6.6.0.632
DEWETRON TRION API              | 6.6.0.632
DEWETRON TRION driver           | 6.6.0.632
DEWETRON DEWE2 driver           | 6.6.0.632

## Files
DEWETRON-TRION-Applications-6.6.0.632.exe

## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R6.6 or higher
* Windows 10 64-Bit or better

## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade

## New Features and most important bugfixes
* TRION(3)-1820-MULTI:
  * Input coupling (highpass filter) overshoot fixed with 0.15Hz filter
* TRIONet3 support
* TRION(3)-Power:
  * TRION SUB-XV support
* TRION3-SUB-8:
  * TRION SUB-XV support

## Known Limitations
* None

DEWETRON TRION R6.6.1 Setup.exe (DEWETRON-TRION-Applications-6.6.1.1146.exe - 198.31 MB)
md5: 7d6f8a13b0cd10bac0a0c5bb7c45b731
Version: R6.6.1
Releasedate: 2023-09-14
OS Compatibility: Windows

Show notes

## 2023-09-14 Release Notice DEWETRON TRION API R6.6.1

Revision: 45fadabcfe6f627121d9a4fc8a177236070b5621

Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 6.6.1.1146
DEWETRON TRION API              | 6.6.1.1146
DEWETRON TRION driver           | 6.6.1.1146
DEWETRON DEWE2 driver           | 6.6.1.1146

## Files
DEWETRON-TRION-Applications-6.6.1.1146.exe

## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R6.6.1 or higher
* Windows 10 64-Bit or better

## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade

## New Features and most important bugfixes
* NEX[DAQ]-200 device support
* PTP Master functionality for DEWE3-OPT-IRIG/PTP
* TRION(3)-Power:
  * TRION SUB-XV fixed
* TRION3-SUB-8:
  * TRION SUB-XV fixed
* PUREC
  * Fixed MSI detection issue
* CB16D
  * Fixed MSI detection issue

## Known Limitations
* None

## Firmwares

HW Support TRION modules        | Firmware
--------------------------------|-----------
TRION3-1810M-POWER-4            | FW: x0077
TRION-1810-HV-4                 | FW: x0077
TRION-1810-HV-8                 | FW: x0077
TRION-1820-POWER-4              | FW: x0077
TRION-1810M-POWER-4             | FW: x0077
TRION3-1810-SUB-8               | FW: x0019

HW Support DEWE3 chassis        | Firmware
--------------------------------|-----------
DEWE3-A4                        | FW: x0036   MCU: 0x01000109
DEWE3-M4                        | FW: x0036   MCU: 0x01000109

DEWETRON TRION R6.6.1 Zip (DEWETRON TRION R6.6.1.zip - 198.11 MB)
md5: 0900a3b6cb4bf9fada9f5bfbd777a8e4
Version: R6.6.1
Releasedate: 2023-09-14
OS Compatibility: Windows

Show notes

## 2023-09-14 Release Notice DEWETRON TRION API R6.6.1

Revision: 45fadabcfe6f627121d9a4fc8a177236070b5621

Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 6.6.1.1146
DEWETRON TRION API              | 6.6.1.1146
DEWETRON TRION driver           | 6.6.1.1146
DEWETRON DEWE2 driver           | 6.6.1.1146

## Files
DEWETRON-TRION-Applications-6.6.1.1146.exe

## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R6.6.1 or higher
* Windows 10 64-Bit or better

## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade

## New Features and most important bugfixes
* NEX[DAQ]-200 device support
* PTP Master functionality for DEWE3-OPT-IRIG/PTP
* TRION(3)-Power:
  * TRION SUB-XV fixed
* TRION3-SUB-8:
  * TRION SUB-XV fixed
* PUREC
  * Fixed MSI detection issue
* CB16D
  * Fixed MSI detection issue

## Known Limitations
* None

## Firmwares

HW Support TRION modules        | Firmware
--------------------------------|-----------
TRION3-1810M-POWER-4            | FW: x0077
TRION-1810-HV-4                 | FW: x0077
TRION-1810-HV-8                 | FW: x0077
TRION-1820-POWER-4              | FW: x0077
TRION-1810M-POWER-4             | FW: x0077
TRION3-1810-SUB-8               | FW: x0019

HW Support DEWE3 chassis        | Firmware
--------------------------------|-----------
DEWE3-A4                        | FW: x0036   MCU: 0x01000109
DEWE3-M4                        | FW: x0036   MCU: 0x01000109

DEWETRON TRION R6.7.2 Zip (DEWETRON TRION R6.7.2.zip - 199.18 MB)
md5: e13858f37b69e7d8ff27f3a71e3d1dd9
Version: R6.7.2
Releasedate: 2023-12-04
OS Compatibility: Windows

Show notes

## 2023-12-04 Release Notice DEWETRON TRION API R6.7.2

Revision: 6e29cade2bda4c122e6674a6263aeb6b6bb16c2c

Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 6.7.2.2175
DEWETRON TRION API              | 6.7.2.2175
DEWETRON TRION driver           | 6.7.2.2175
DEWETRON DEWE2 driver           | 6.7.2.2175

## Files
DEWETRON-TRION-Applications-6.7.2.2175.exe

## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R6.7.1 or higher
* Windows 10 64-Bit or better

## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade

## New Features and most important bugfixes
* TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal
* trion_cal: TRION-18XX-MULTI, allow AUTO and 0Hz for HP-Filter in XML
* CHASSIS-CONTROLLER-V2: Fixed an issue with spikes when using CAN OUT (new fw)

## Known Limitations
* ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected

## New Firmwares

HW Support DEWE3 chassis        | Firmware
--------------------------------|-----------
DEWE3-A4                        | FW: x0038   MCU: 0x01000109
DEWE3-M4                        | FW: x0038   MCU: 0x01000109

 

DEWETRON TRION R6.7.2 Setup.exe (DEWETRON-TRION-Applications-6.7.2.2175.exe - 199.38 MB)
md5: 44ed2e9fb743f92448b053767fcc8199
Version: R6.7.2
Releasedate: 2023-12-04
OS Compatibility: Windows

Show notes

## 2023-12-04 Release Notice DEWETRON TRION API R6.7.2

Revision: 6e29cade2bda4c122e6674a6263aeb6b6bb16c2c

Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 6.7.2.2175
DEWETRON TRION API              | 6.7.2.2175
DEWETRON TRION driver           | 6.7.2.2175
DEWETRON DEWE2 driver           | 6.7.2.2175

## Files
DEWETRON-TRION-Applications-6.7.2.2175.exe

## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R6.7.1 or higher
* Windows 10 64-Bit or better

## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade

## New Features and most important bugfixes
* TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal
* trion_cal: TRION-18XX-MULTI, allow AUTO and 0Hz for HP-Filter in XML
* CHASSIS-CONTROLLER-V2: Fixed an issue with spikes when using CAN OUT (new fw)

## Known Limitations
* ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected

## New Firmwares

HW Support DEWE3 chassis        | Firmware
--------------------------------|-----------
DEWE3-A4                        | FW: x0038   MCU: 0x01000109
DEWE3-M4                        | FW: x0038   MCU: 0x01000109

 

TRION sub-modules datasheet (TRION_sub_modules_datasheet_151ex.pdf - 711 KB)
md5: c314490ad91e3da83eb3d204db520774
Version: 1.5.1
Releasedate: 2024-01-12
Language: English
LabVIEW TRION(3) driver (dewetron_gmbh_lib_dewetron_drivers-0.0.0.13.zip - 3.72 MB)
md5: 53f257e45be20402c981223eed915eba
Version: 0.0.0.13
Releasedate: 2022-10-11
OS Compatibility: Windows

Show notes

+ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + +
2022-10-11 Release Notice dewetron_gmbh_lib_dewetron_drivers-0.0.0.13.zip

* Files:
** dewetron_gmbh_lib_dewetron_drivers-0.0.0.13.zip

* Version: 0.0.0.13

* Requirements:
** Windows 10 64-Bit
** NI LabVIEW 2018 or higher (32 bit and 64 bit)
** DEWETRON-TRION-Applications-6.3.0.63500 or higher

* Installation procedure
** Can be installed by using LabVIEW Package Manager

* Description
** Native LabVIEW driver for TRION & TRION3 modules
** Documentation included in the source code
** Dedicated functions included in separate VIs for hardware configuration
** Programming examples for different use cases included
** Supports TRION & TRION3 modules in DEWE2 (incl. TRIONet(3)) & DEWE3 chassis
** Supports one NEX[DAQ] connected via USB or Ethernet
** Synchronization via internal DEWE2/DEWE3 chassis clock
** Supported Channel types:
*** Analog inputs (AI)
*** Analog outputs (AO)
*** Digital inputs (DI)
*** Digital outputs (DO)
*** Counter inputs (CNT)
*** CAN message receive
*** CAN message decode (for LabVIEW 32 bit)
*** Recognition of MSIs & SUB modules

* Known Limitations
** External Synchronization signals not supported
** Synchronization of several DEWE2/DEWE3 chassis via TRION Sync I/O not supported
** More than one NEX[DAQ] synchronized via PTP connected to one PC
** Maximum tested data rate: 200 MB/s (corresponds to 48 AI á 1 MS/s á 24 bit)
** CAN message decode (for LabVIEW 64 bit due to missing LabVIEW library)
** CAN output 

* Changes from v0.0.0.8 to v0.0.0.13
** New supported channel types:
*** Analog outputs (AO)
*** Digital outputs (DO)
*** CAN message receive
*** CAN message decode (for LabVIEW 32 bit)
** TRIONet supported

* Changes from v0.0.0.7 to v0.0.0.8
** If-1 is entered for ShuntResistance the Parameter won't be set
** The number format has now also been set to a point as a decimal separator for the InputOffset
** Only integer values ​​can now be entered for ShuntResistance