|
Notes for dewetron-apps-8.3.1.997-rhel9.install.gz
## 2026-11-13 Release Notice DEWETRON Oxygen/TRION for Linux R8.3.1 x64
Revision: 29aed4dbb8365b7c6e6427add05cb9f911ca9484
Components | Version
--------------------------------|--------------------------
DEWETRON Oxygen | 8.3.1.11034
DEWETRON TRION | 8.3.1.11034
## Files
Debian GNU/Linux 12: dewetron-apps-8.3.1.1008-debian12_x64.install.gz
Debian GNU/Linux 13: dewetron-apps-8.3.1.4-debian13_x64.install.gz
Red Hat Enterprise Linux 10: dewetron-apps-8.3.1.220-rhel10.install.gz
Red Hat Enterprise Linux 9: dewetron-apps-8.3.1.997-rhel9.install.gz
Ubuntu 22.04 LTS: dewetron-apps-8.3.1.994-ubuntu2204_x64.install.gz
Ubuntu 24.04 LTS: dewetron-apps-8.3.1.1004-ubuntu2404_x64.install.gz
Ubuntu 26.04 LTS: dewetron-apps-8.3.1.4-ubuntu2604_x64.install.gz
## Requirements
* 8.x Software License required!
* OS: Linux 64bit, one of the distributions listed under Files
* CPU: Intel i3 3rd gen. or better
* Minimum RAM: 8 GB
* Recommended RAM: 16 GB (for high sample rates and channel counts)
* DAQ Hardware:
- DEWETRON TRION and TRION3 (DEWETRON TRION Software R8.3.1)
## New Features
* Software Channels: Transfer function based on white noise as input signal, blockwise and overall.
* Software Channels: CPB analysis offers the same overall output channels and calculation modes as the FFT analysis.
* Software Channels: Broadband impedance test procedure for grid connected power converters.
* OXYGEN-NET: XR decoder support for the OXYGEN-NET master.
* Sync Settings: Individual sync status for each node (OXYGEN-NET and TRIONet).
* SCPI: New commands to select sensors from the sensor database.
* SCPI: New command for the freeze button.
* SCPI: New commands to access the OXYGEN event list.
* Hardware: Support for DEWE3-M12S.
## Improvements
* Instruments: Continuous automatic X-axis scaling from measurement start to the current time.
* Instruments: Matrix sampler supports more levels, labels for levels and can hide the contour lines.
* Instruments: Recorder type instruments support dashed and dotted line types.
* Instruments: The numerical display of the saturation meter can be hidden.
* Channel List: Changed the order of chassis and of the XR modules in an XR decoder channel section.
* Pin Out & Connections: The window size is adapted dynamically.
* Software Channels: IIR filter allows uneven orders (1, 3, 5, 7, 9).
* Simulation: The state of simulated status channels can be set manually.
* Python SDK: Improved support for Python plugins.
* Added support for Ubuntu 26.04, Debian 13 and RHEL 10.
## Fixes
* Fixed an issue when the TRION3-AOUT output kept running after the channel was switched off.
* Fixed an issue when voltage excitation was not switched off on disabled TRION channels.
* Fixed an issue when the bridge resistance of TRION-2402-MULTI and TRION-2400-dSTG could not be set after selecting a quarter bridge.
* Fixed an issue when the CAN data stream of TRION3-CAN-FD stopped or did not start on some cards.
* Fixed issues when using OBDII over TRION3-CAN-FD.
* Fixed an issue when the acquisition did not start with a loaded TRIONet setup and auto claim disabled.
* Fixed an issue when the modules of a TRION-1802-dLV RS-485 port were not always detected.
* Fixed an Oxygen crash caused by the QML garbage collector.
* Fixed an Oxygen crash when opening DMD files containing Japanese characters.
* Fixed an Oxygen crash on customer setups.
* Fixed an Oxygen crash in OXYGEN-NET when synchronizing a remote node.
* Fixed an issue when the power manager channels had no data after loading a setup.
* Fixed an issue when the power instrument showed wrong values with multiple power groups.
* Fixed an issue when the harmonic vector of the power harmonics held invalid values after increasing the fundamental frequency.
* Fixed an issue when the resolver multiple pole pair angle did not work at low speeds.
* Fixed an issue when the current excited QB scaling was not transferred in SI units to PAK.
* Fixed the reduced sample rate of CSV/TXT exports with mixed channels.
* Fixed an issue when CSV import based on sample rate delivered no data and when it contained Chinese characters.
* Fixed an issue when files recorded with multi files or event based recording were overwritten.
* Fixed an issue when the data of the second and following files of a multi file recording was lost after saving a DMD file.
* Fixed an issue when the setting "Split by file size" was not saved to the setup file.
* Fixed an issue when the DMD reader did not report access denied errors and when unfinished files containing only slow data showed nothing.
* Fixed an issue when the SCPI port number could not be changed.
* Fixed SCPI returning NaN for continuous statistics of power group channels.
* Fixed an issue when the Power Manager plugin was loaded on DEWE3-A8. |