NEXDAQ

 
belongs to: NEXDAQ
You have to be logged in to access the downloads. Please use the login form on the top of the page.
NEXDAQ 3D-drawing STP (NEXDAQ_Export3D.stp - 23.06 MB)
md5: ba1a6081e683a039ccb273c0615f0529
Version: 2024/02
Releasedate: 2024/02
NEXDAQ Brochure (NEXDAQ_by_DEWETRON.pdf - 3.31 MB)
md5: 3655f2d53a397b4530ef12e088463c8a
Version: 2023/06
Releasedate: 2023/06
Language: English
NEXDAQ Broschüre (NEXDAQ_von_DEWETRON.pdf - 3.31 MB)
md5: 530798693643f80d52b22205e03daba4
Version: 06/2023
Releasedate: 2023/06
Language: German
NEXDAQ Datasheet 1.0.4 (NEX[DAQ]_datasheet_104ex.pdf - 1.07 MB)
md5: afa1e8bf20bae98fee680a8b777f98df
Version: 1.0.4
Releasedate: 2024-07-11
Language: English
NEXDAQ Firmware R7.2.1: Remote Update (01_NEXDAQ_R7.2.1_Update_Remote.zip - 147.72 MB)
md5: ce85be6a4d9d45632cb7f944dada0639
Version: R7.2.1
Releasedate: 2024-08-27

Show notes

## 2024-08-27 Release Notice DEWETRON Nex[DAQ] Firmware R7.2.1

Revision: 876a648bcaebd47fe225e89ab132256fce382190

Components                      | Version
--------------------------------|--------------------------
OS                              | Yocto 4.0.4 kirkstone
DEWETRON TRIONet Server         | 7.2.1.5243
DEWETRON TRION API              | 7.2.1.5243
NEXDAQ Driver                   | 7.2.1.5243

## Files
### NEXDAQ remote update
nexdaq_swupdate_7.2.1.5243_194.swu

## Requirements
* All NEX[DAQ] devices used with OXYGEN should be updated to the image included in this release

## Known Limitations
* Limited bandwith does not allow enabling all AI, DI, CNT channels with 1MS.
* Maximum stable settings:
  * 8 AI channels with 1MHz sample rate
  * 8 DI and 4 DO channels with 1MHz sample rate
  * 4 CNT channels at 200kHz
* Do not use more than 3 connected devices NEX[DAQ]-200 without additional performance testing.

NEXDAQ Firmware R6.7.3: Remote Update (01_NEXDAQ_R6.7.3_Update_Remote.zip - 142.59 MB)
md5: 3d77c104cd3236fd5d0682d3827cf834
Version: R6.7.3
Releasedate: 2024-02-14

Show notes

## 2023-02-14 Release Notice DEWETRON Nex[DAQ] Firmware R6.7.3

Revision: 7aa6f0e1381c890da5d0df82d545e1a3cac015d7

Components                      | Version
--------------------------------|--------------------------
OS                              | Yocto 4.0.4 kirkstone
DEWETRON TRIONet Server         | 6.7.3.2897
DEWETRON TRION API              | 6.7.3.2897
NEXDAQ Driver                   | 6.7.3.2897

## Files
### NEXDAQ remote update
update-image-nexdaq-6.7.3.swu

## Requirements
* All NEX[DAQ] devices used with OXYGEN 6.7 should be updated to the image included in this release

## New Features and most important bugfixes:
* Fix device crashing when enabling or disabling a CAN channel

## Known Limitations
* To fix a hardware overflow sometimes a power cycle is needed

 

NEXDAQ Firmware R7.0.0: Remote Update (01_NEXDAQ_R7.0.0_Update_Remote.zip - 143.15 MB)
md5: f6dea98fef9a4684205d794c047fcb64
Version: R7.0.0
Releasedate: 2024-02-14

Show notes

## 2024-02-01 Release Notice DEWETRON Nex[DAQ] Firmware R7.0.0

Revision: c8730c64bd0f421a4b0a87b70977e5b072fa9e1e

Components                      | Version
--------------------------------|--------------------------
OS                              | Yocto 4.0.4 kirkstone
DEWETRON TRIONet Server         | 7.0.0.2733
DEWETRON TRION API              | 7.0.0.2733
NEXDAQ Driver                   | 7.0.0.2733

## Files
### NEXDAQ remote update
update-image-nexdaq-7.0.0.swu

## Requirements
* All NEX[DAQ] devices used with OXYGEN should be updated to the image included in this release

## New Features and most important bugfixes:
* Allow device network configuration even if ip settings do not match
* Node default name is the serial number
* CAN-FD bittiming added

## Known Limitations
* To fix a hardware overflow sometimes a power cycle is needed

## Firmwares

HW Support                      | Firmware
--------------------------------|-----------
NEX[DAQ]-200                    | FW: x0051

NEXDAQ Firmware R7.1.1: Remote Update (01_NEXDAQ_R7.1.1_Update_Remote.zip - 146.57 MB)
md5: b7762f691e3b190081aaa0bcb1da1256
Version: R7.1.1
Releasedate: 2024-05-27

Show notes

## 2024-05-27 Release Notice DEWETRON Nex[DAQ] Firmware R7.1.1

Revision: 26c98ba4677bc1a19d7e0590475122b6c54e05d3

Components                      | Version
--------------------------------|--------------------------
OS                              | Yocto 4.0.4 kirkstone
DEWETRON TRIONet Server         | 7.1.1.4060
DEWETRON TRION API              | 7.1.1.4060
NEXDAQ Driver                   | 7.1.1.4060

## Files
### NEXDAQ remote update
nexdaq_swupdate_7.1.1.4060_155.swu

## Requirements
* All NEX[DAQ] devices used with OXYGEN should be updated to the image included in this release

## Fixes:
* Version update to 7.1.1 to match other artefacts

NEXDAQ Firmware R6.7.2: Remote Update (01_NEXDAQ_R6.7.2_Update_Remote.zip - 141.32 MB)
md5: 6f19fe13e98b9f0d3726a9c282bc0538
Version: R6.7.2
Releasedate: 2023-12-04

Show notes

## 2023-12-04 Release Notice DEWETRON Nex[DAQ] Firmware R6.7.2

Revision: 6e29cade2bda4c122e6674a6263aeb6b6bb16c2c

Components                      | Version
--------------------------------|--------------------------
OS                              | Yocto 4.0.4 kirkstone
DEWETRON TRIONet Server         | 6.7.2.2175
DEWETRON TRION API              | 6.7.2.2175
NEXDAQ Driver                   | 6.7.2.2175

## Files
### NEXDAQ remote update
update-image-nexdaq-6.7.2.swu

## Requirements
* All NEX[DAQ] devices used with OXYGEN should be updated to the image included in this release

## New Features and most important bugfixes:
* CAN: Added missing 2MBit Baudrate
* PTP: Added PTP transparent clock
* PTP: Improved servo configuration
* Ethernet: Default IP configuration is DHCP
* Fixed kernel crash in overflow situations
* Watchdog enabled

## Known Limitations
* To fix a hardware overflow sometimes a power cycle is needed


## Firmwares

HW Support                      | Firmware
--------------------------------|-----------
NEX[DAQ]-200                    | FW: x0049

NEXDAQ Firmware R6.6.1: Remote Update (01_NEXDAQ_R6.6.1_Update_Remote.zip - 141.00 MB)
md5: f27ea5ae4ce538f20eeb2c01f4d8c65f
Version: R6.6.1
Releasedate: 2023-09-14

Show notes

## 2023-09-14 Release Notice DEWETRON Nex[DAQ] Firmware R6.6.1

Revision: 45fadabcfe6f627121d9a4fc8a177236070b5621

Components                      | Version
--------------------------------|--------------------------
OS                              | Yocto 4.0.4 kirkstone
DEWETRON TRIONet Server         | 6.6.1.1146
DEWETRON TRION API              | 6.6.1.1146
NEXDAQ Driver                   | 6.6.1.1146


## Files
### NEXDAQ remote update
update-image-nexdaq-6.6.1.swu

## Requirements

## New Features and most important bugfixes:
* NEX[DAQ]-200 device support
  * Basic support for synchronization of multiple devices
## Known Limitations
* PTP synchronization sometimes exceeds correction limit (OOR) depending on network usage


## Firmwares

HW Support                      | Firmware
--------------------------------|-----------
NEX[DAQ]-200                    | FW: x0046

 

DEWETRON TRION R7.2.1 Setup.exe (DEWETRON-TRION-Applications-7.2.1.5243.exe - 225.80 MB)
md5: 0fd7bc6f878ac0c53358e0610b8b705d
Version: R7.2.1
Releasedate: 2024-08-27
OS Compatibility: Windows

Show notes

## 2024-08-27 Release Notice DEWETRON TRION API R7.2.1

Revision: 876a648bcaebd47fe225e89ab132256fce382190

Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 7.2.1.5243
DEWETRON TRION API              | 7.2.1.5243
DEWETRON TRION driver           | 7.2.1.5243
DEWETRON DEWE2 driver           | 7.2.1.5243

## Files
DEWETRON-TRION-Applications-7.2.1.5243.exe

## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.2.0 or higher
* Windows 10 64-Bit or better

## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade

## Fixes
* NEX[DAQ]-1000 simulation sample rate divider support fixed.

DEWETRON TRION R7.2.1 Zip (DEWETRON TRION R7.2.1.zip - 225.61 MB)
md5: f75aef26aabb1a61616420da19f19eb2
Version: R7.2.1
Releasedate: 2024-08-27
OS Compatibility: Windows

Show notes

## 2024-08-27 Release Notice DEWETRON TRION API R7.2.1

Revision: 876a648bcaebd47fe225e89ab132256fce382190

Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 7.2.1.5243
DEWETRON TRION API              | 7.2.1.5243
DEWETRON TRION driver           | 7.2.1.5243
DEWETRON DEWE2 driver           | 7.2.1.5243

## Files
DEWETRON-TRION-Applications-7.2.1.5243.exe

## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.2.0 or higher
* Windows 10 64-Bit or better

## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade

## Fixes
* NEX[DAQ]-1000 simulation sample rate divider support fixed.

NEXDAQ Technical Reference 1.0.2 (NEXDAQ_Technical_Reference_102ex.pdf - 9.72 MB)
md5: 9d8072cd64e5b048b755a901b77da9e9
Version: 1.0.2
Releasedate: 2024-07-11
Language: English