ORION series

 

 
belongs to: Discontinued Systems
You have to be logged in to access the downloads. Please use the login form on the top of the page.
DEWE-ORION Brochure (dewetron_dewe-orion_e.pdf - 1.10 MB)
md5: 4717b031c373d77444c848c54bedfb08
Version: English
Releasedate: 2014/08/12
DEWE-ORION-0424-200 Technical reference manual (dewe-orion-0424-200_105ex.pdf - 5.47 MB)
md5: 76a0bb08f285e6038d854e54abd665fa
Version: 1.0.5
Releasedate: 2013/04/29
DEWE-ORION-0816-100x Technical Reference Manual (dewe-orion-0816-100x_techref_207e.pdf - 2.51 MB)
md5: 34a67931a0e8c7e700617fb65ba991cf
Version: 2.0.7
Releasedate: 11/11/2015
Language: english
DEWE-ORION-0816-5M/10 Technical Reference Manual (dewe-orion-0816-5m_10m_techref_102e.pdf - 2.14 MB)
md5: 23dc974f8cf25e5be0121bf38df0f63c
Version: 1.0.2
Releasedate: 04/07/2015
Language: english
DEWE-ORION-0824-20x Technical reference manual (dewe-orion-0824-20x_112ex.pdf - 8.32 MB)
md5: 68e7acae70fa7722dc54e0a61973542d
Version: 1.1.2
Releasedate: 2014/03/19
DEWE-ORION-1616-100x Technical reference manual (dewe-orion-1616-100x_techref_105ex.pdf - 8.24 MB)
md5: 9012f7b1beb1795385866ab009c050bc
Version: 1.0.5
Releasedate: 2014/03/19
DEWE-ORION-1616-10x Technical reference manual (dewe-orion-1616-10x_techref_120ex.pdf - 7.43 MB)
md5: 7ee5380a3908f8979b38e4f17593dd2c
Version: 1.2.0
Releasedate: 2014/03/19
DEWE-ORION-1616-50x Technical Reference Manual (dewetron_dewe-orion-1616-50x_ex.pdf - 7.71 MB)
md5: dfd1bfec649f8a032a3e95a943f175cf
Version: English
Releasedate: 2013/04/29
DEWE-ORION-1616-50x Technical Reference Manual (dewe-orion-1616-50x_techref_117ex.pdf - 7.71 MB)
md5: dfd1bfec649f8a032a3e95a943f175cf
Version: 1.1.7
Releasedate: 2013/04/29
DEWE-ORION-1622-10x Technical Reference Manual (dewe-orion-1622-10x_108ex.pdf - 8.00 MB)
md5: 3a1d6076810d167e85754de3bb66919d
Version: 1.0.8
Releasedate: 2014/03/19
DEWE-ORION-1624 Technical Reference Manual (dewe-orion-1624_techref_109ex.pdf - 6.65 MB)
md5: 82b785c2ddbc42558a0b3bab00df55d8
Version: 1.0.9
Releasedate: 2013/04/26
DEWE-ORION-1624-20x Technical Reference Manual (dewe-orion-1624-20x_109e.pdf - 2.97 MB)
md5: 43d3d7cd1852a665a014a3020ef91a82
Version: 1.0.9
Releasedate: 2016/10/07
Language: English
ORION-EXP-CNT6 Technical Reference Manual (orion-exp-cnt6_techref_101ex.pdf - 1.50 MB)
md5: 248a9498f7bc1cbaaf9f702b2af6fc26
Version: 1.0.1
Releasedate: 2009/04/27
Orion Driver (orion_driver_x86.zip - 644 KB)
md5: 62b7fed7bfd17370854c05c6bdee95ab
Version: DAQ: 1.0.0.90 / DSA: 3.0.0.79
OS Compatibility: Windows 2000, Windows XP | 32-bit
OrionDAQ_Driver_2.3.1.0 (DAQ-BOARDS_DRIVER_v2.3.1.0.zip - 5.91 MB)
md5: a8523f4f09ac9e528c7a6894684850b4
Version: 2.3.1.0
Releasedate: 2018-07-13
OS Compatibility: Win7 32-bit/ 64-bit | Win10 64-bit

Show notes

-------------------------------------------------------------------------------------------------------------

Release Notice ORION DAQ Driver v2.3.1.0

2018-07-13

 

* Version: 2.3.1.0

 

* Components:

** 32-bit DAQ driver 

** 64-bit DAQ driver

 

* New Features:

** supports Win10 64-bit systems (Winx64)

** supports Win7 32-/64-Bit systems

 

* Bugfixes:

** FW version number indication fixed for Orion 0816-1000N and Orion 1616-1000 (correct "101", wrong "901")

** ORION co-installer fixed to support Win10x64

** external clocking with DEWE-Clock fixed

 

* Known Limitation:

** At all times only one instance of the DAQ driver is allowed.

** Installing the driver without Administrator privileges will result in an incorrect installation

** When Orion 1616-50x, Orion 0816-100x or Orion 1616-100x are used in the system, the DMA buffer size has to be adjusted manually in order to support all channels of the cards. For the detailed descritpion please refer to <<Application_Note_64 Bit Driver.pdf>>

** Measurement start: If no CAN frames are received before the internal 24-bit counter overflows (~3 minutes @100 Hz), the overflow is not considered and the CAN timestamps are wrong. Workaround: add a CAN channel that always sends data.  (problem @ BOSCH, will be fixed for ORION and Oxygen, was already fixed for TRION, won´t be fixed for ORION and DS => DS issue)

OrionDSA_Driver_5.0.1.0 (DSA-BOARDS_DRIVER_v5.0.1.0.zip - 21.30 MB)
md5: 6c897c016a0064a78479f476539bfb9f
Version: 5.0.1.0
Releasedate: 2018-07-13
OS Compatibility: Win7 32-bit/ 64-bit | Win10 64-bit

Show notes

-------------------------------------------------------------------------------------------------------------

Release Notice ORION DSA Driver v5.0.1.0

2018-07-13

 

* Version: 5.0.1.0

 

* Components:

** 32-bit DAQ driver 

** 64-bit DAQ driver

 

* New Features:

** supports Win10 64-bit systems (Winx64)

** supports Win7 32-/64-Bit systems

 

* Bugfixes:

** FW version number indication fixed for Orion 0816-1000N and Orion 1616-1000 (correct "101", wrong "901")

** ORION co-installer fixed to support Win10x64

** external clocking with DEWE-Clock fixed

 

* Known Limitation:

** At all times only one instance of the DAQ driver is allowed.

** Installing the driver without Administrator privileges will result in an incorrect installation

** Measurement start: If no CAN frames are received before the internal 24-bit counter overflows (~3 minutes @100 Hz), the overflow is not considered and the CAN timestamps are wrong. Workaround: add a CAN channel that always sends data.  (problem @ BOSCH, will be fixed for ORION and Oxygen, was already fixed for TRION, won´t be fixed for ORION and DS => DS issue)